noneXimena Chávez Pinacho

108 Spicer points

0 Followers

Posts

Information

  • Fitting of the O 1s photoemision spectrum, from a Y2(CO3)3/LaB6 sample. The spectrum was fitted employing three Voigt peaks. Data were provided by Vincent Crist (the use of the spectrum requieres acknowledging XPS library website, https://xpslibrary.com/).
    Read more

    Files :

    • You must be logged-in to download data

    Information about the sample:

    • Shape: Flat surface

    • Sample material: Y2(CO3)3/LaB6

    • Elements: Y C O La B

    • Sample composition: Y2(CO3)3

    Data acquisition parameters:

    • Photon source: Al Ka monochromatic

    Equipment and analysis software:

    • Software used: aanalyzer

    aanalyzer_832_image_14.jpg
  • Fitting of the O 1s photoemision spectrum, from a CuCO3 powder on tape. The spectrum was fitted employing three Voigt peaks. Data were provided by Vincent Crist (the use of the spectrum requieres acknowledging XPS library website, https://xpslibrary.com/).
    Read more

    Files :

    • You must be logged-in to download data

    Information about the sample:

    • Shape: Powder

    • Sample material: CuCO3

    • Elements: Cu C O

    • Sample composition: CuCO3

    Data acquisition parameters:

    • Photon source: Al Ka monochromatic

    Equipment and analysis software:

    • Software used: aanalyzer

    aanalyzer_836_image_14.jpg
  • Fitting of the O 1s photoemision spectrum, from a 3 mm Sb2O3 pellet. The spectrum was fitted employing two Voigt peaks. Data were provided by Vincent Crist (the use of the spectrum requieres acknowledging XPS library website, https://xpslibrary.com/).
    Read more

    Files :

    • You must be logged-in to download data

    Information about the sample:

    • Shape: Flat surface

    • Sample material: Sb2O3

    • Elements: Sb O

    • Sample composition: Sb2O3

    Data acquisition parameters:

    • Photon source: Al Ka monochromatic

    • Pass energy: 30.01

    Equipment and analysis software:

    • Software used: aanalyzer

    aanalyzer_827_image_14.jpg
  • Fitting of the O 1s photoemision spectrum, from a K2O/SiO2 exposed bulk mesh. The spectrum was fitted employing two Voigt peaks. Data were provided by Vincent Crist (the use of the spectrum requieres acknowledging XPS library website, https://xpslibrary.com/).
    Read more

    Files :

    • You must be logged-in to download data

    Information about the sample:

    • Shape: Flat surface

    • Sample material: K2O/SiO2

    • Elements: K O Si

    • Sample composition: K2O

    Data acquisition parameters:

    • Photon source: Al Ka monochromatic

    • Pass energy: 54.99

    Equipment and analysis software:

    • Software used: aanalyzer

    aanalyzer_828_image_14.jpg
  • Fitting of the O 1s photoemision spectrum, from a 3 mm TeO2 pellet. The spectrum was fitted employing three Voigt peaks. Data were provided by Vincent Crist (the use of the spectrum requieres acknowledging XPS library website, https://xpslibrary.com/).
    Read more

    Files :

    • You must be logged-in to download data

    Information about the sample:

    • Shape: Flat surface

    • Sample material: TeO2

    • Elements: Te O

    • Sample composition: TeO2

    Data acquisition parameters:

    • Photon source: Al Ka monochromatic

    • Pass energy: 54.76

    Equipment and analysis software:

    • Software used: aanalyzer

    aanalyzer_830_image_14.jpg
  • Fitting of the O 1s photoemision spectrum, from a 3 mm Ga2O3 pellet. The spectrum was fitted employing three Voigt peaks. Data were provided by Vincent Crist (the use of the spectrum requieres acknowledging XPS library website, https://xpslibrary.com/).
    Read more

    Files :

    • You must be logged-in to download data

    Information about the sample:

    • Shape: Flat surface

    • Sample material: Ga2O3

    • Elements: Ga O

    • Sample composition: Ga2O3

    Data acquisition parameters:

    • Photon source: Al Ka monochromatic

    • Pass energy: 54.76

    Equipment and analysis software:

    • Software used: aanalyzer

    aanalyzer_831_image_14.jpg
  • Fitting of the O 1s photoemision spectrum, from a MgCO3 powder on tape. The spectrum was fitted employing two Voigt peaks. Data were provided by Vincent Crist (the use of the spectrum requieres acknowledging XPS library website, https://xpslibrary.com/).
    Read more

    Files :

    • You must be logged-in to download data

    Information about the sample:

    • Shape: Powder

    • Sample material: MgCO3

    • Elements: Mg C O

    • Sample composition: MgCO3

    Data acquisition parameters:

    • Photon source: Al Ka monochromatic

    Equipment and analysis software:

    • Software used: aanalyzer

    aanalyzer_833_image_14.jpg
  • Fitting of the O 1s photoemision spectrum, from a LiCO3 sample produced by a CO2 attack on LiOH powder. The spectrum was fitted employing three Voigt peaks. Data were provided by Vincent Crist (the use of the spectrum requieres acknowledging XPS library website, https://xpslibrary.com/).
    Read more

    Files :

    • You must be logged-in to download data

    Information about the sample:

    • Shape: Powder

    • Sample material: LiCO3

    • Elements: Li C O

    • Sample composition: LiCO3

    Data acquisition parameters:

    • Photon source: Al Ka monochromatic

    Equipment and analysis software:

    • Software used: aanalyzer

    aanalyzer_834_image_14.jpg
  • Fitting of the C 1s photoemision spectrum, from a CuCO3 powder on tape. The spectrum was fitted employing four Voigt peaks. Data were provided by Vincent Crist (the use of the spectrum requieres acknowledging XPS library website, https://xpslibrary.com/).
    Read more

    Files :

    • You must be logged-in to download data

    Information about the sample:

    • Shape: Powder

    • Sample material: CuCO3

    • Elements: Cu C O

    • Sample composition: CuCO3

    Data acquisition parameters:

    • Photon source: Al Ka monochromatic

    Equipment and analysis software:

    • Software used: aanalyzer

    aanalyzer_864_image_14.jpg
  • Fitting of the C 1s photoemision spectrum, from a Y2(CO3)3/LaB6 sample. The spectrum was fitted employing three Voigt peaks. Data were provided by Vincent Crist (the use of the spectrum requieres acknowledging XPS library website, https://xpslibrary.com/).
    Read more

    Files :

    • You must be logged-in to download data

    Information about the sample:

    • Shape: Flat surface

    • Sample material: Y2(CO3)3

    • Elements: Y C O

    • Sample composition: Y2(CO3)3

    Data acquisition parameters:

    • Photon source: Al Ka monochromatic

    Equipment and analysis software:

    • Software used: aanalyzer

    aanalyzer_862_image_14.jpg
  • Fitting of the C 1s photoemision spectrum, from a MgCO3 powder on tape. The spectrum was fitted employing four Voigt peaks. Data were provided by Vincent Crist (the use of the spectrum requieres acknowledging XPS library website, https://xpslibrary.com/).
    Read more

    Files :

    • You must be logged-in to download data

    Information about the sample:

    • Shape: Powder

    • Sample material: MgCO3

    • Elements: Mg C O

    • Sample composition: MgCO3

    Data acquisition parameters:

    • Photon source: Al Ka monochromatic

    Equipment and analysis software:

    • Software used: aanalyzer

    aanalyzer_863_image_14.jpg
  • Fitting of the Te 3d photoemision spectrum, from a 3 mm TeO2 pellet. The spectrum was fitted employing four Voigt peaks, of which two were doublets (purple and olive green). Data were provided by Vincent Crist (the use of the spectrum requieres acknowledging XPS library website, https://xpslibrary.com/).
    Read more

    Files :

    • You must be logged-in to download data

    Information about the sample:

    • Shape: Flat surface

    • Sample material: TeO2

    • Elements: Te O

    • Sample composition: TeO2

    Data acquisition parameters:

    • Photon source: Al Ka monochromatic

    • Pass energy: 54.76

    Equipment and analysis software:

    • Software used: aanalyzer

    aanalyzer_866_image_14.jpg
  • Fitting of the Al 2p photoemision spectrum. The spectrum was fitted employing one doublet Voigt peak. Data were provided by Dr Anders Barlow (the use of the spectrum requieres acknowledging the following article http://dx.doi.org/10.1002/sia.6417).
    Read more

    Files :

    • You must be logged-in to download data

    Information about the sample:

    • Shape: Flat surface

    • Sample material: AlPO4

    • Elements: Al P O

    • Sample composition: TeO2

    Data acquisition parameters:

    • Photon source: Al Ka monochromatic

    • Pass energy: 5

    Equipment and analysis software:

    • Software used: aanalyzer

    aanalyzer_868_image_14.jpg
  • Fitting of the Ge 2p photoemision spectrum. The spectrum was fitted employing four Gaussian peaks and one Voigt peak, all of them being doublets. Data were provided by Vincent Crist (the use of the spectrum requieres acknowledging XPS library website, https://xpslibrary.com/).
    Read more

    Files :

    • You must be logged-in to download data

    Information about the sample:

    • Shape: Flat surface

    • Sample material: Pure germanium

    • Elements: Ge

    • Sample composition: Ge

    Data acquisition parameters:

    • Photon source: Al Ka monochromatic

    Equipment and analysis software:

    • Software used: aanalyzer

    aanalyzer_869_image_14.jpg
  • Fitting of the Ge 2p photoemision spectrum. The spectrum was fitted employing three Voigt peaks, where two of them were correlated by their area (olive green peaks). Data were provided by Vincent Crist (the use of the spectrum requieres acknowledging XPS library website, https://xpslibrary.com/).
    Read more

    Files :

    • You must be logged-in to download data

    Information about the sample:

    • Shape: Powder

    • Sample material: Pure selenium

    • Elements: Se

    • Sample composition: Se

    Data acquisition parameters:

    • Photon source: Al Ka monochromatic

    Equipment and analysis software:

    • Software used: aanalyzer

    aanalyzer_870_image_14.jpg

Full name:

Ximena Chávez Pinacho

Title:

none

organization:

Universidad Autónoma de Querétaro

Country:

Mexico

Number of post in database:

0

Number of post:

Total: 6