Dr. Orlando Cortazar-Martínez

396 Spicer points

1 Followers

Posts

Information

  • Read more
    xpsoasis_222_image_100.jpg
  • Read more

    Files :

    • You must be logged-in to download data

    Information about the sample:

    • Shape: Flat surface

    • Sample material: Aluminum Oxide

    • Elements: Al, O

    • Sample composition: Al2O3, AlO

    Data acquisition parameters:

    • Photon source: Al Ka monochromatic

    • Pass energy: 15

    • Take-off angle: 85-35

    Equipment and analysis software:

    • Software used: aanalyzer

    aanalyzer_715_image_14.jpg
  • Read more

    Files :

    • You must be logged-in to download data

    Equipment and analysis software:

    • Software used: aanalyzer

    aanalyzer_977_image_14.jpg
  • Read more

    Files :

    • You must be logged-in to download data

    Information about the sample:

    • Shape: Flat surface

    • Sample material: Aluminum

    • Elements: Al

    • Sample composition: Al

    Data acquisition parameters:

    • Photon source: Al Ka monochromatic

    • Pass energy: 15

    • Take-off angle: 35-85

    Equipment and analysis software:

    • Brand: Thermofisher

    • Model: Alpha110

    • Spectrometer mode: MonoXPS

    • Software used: AAnalyzer

    xpsoasis_421_image_100.jpgxpsoasis_421_image_100.jpg
  • All spectra were aligned to the reported value of 72.6 eV.
    Read more

    Files :

    • You must be logged-in to download data

    aanalyzer_718_image_14.jpg
  • Read more

    Files :

    • You must be logged-in to download data

    Data acquisition parameters:

    • Photon source: Al Ka

    Equipment and analysis software:

    • Software used: aanalyzer

    aanalyzer_973_image_14.jpg
  • Read more

    Files :

    • You must be logged-in to download data

    Equipment and analysis software:

    • Software used: aanalyzer

    aanalyzer_975_image_14.jpg
  • Read more

    Files :

    • You must be logged-in to download data

    Equipment and analysis software:

    • Software used: aanalyzer

    aanalyzer_976_image_14.jpg
  • Datos de oxigeno O1s para el curso de Principios de Caractrización
    Read more

    Equipment and analysis software:

    • Software used: Analyzer

    xpsoasis_432_image_100.jpg
  • Read more

    Files :

    • You must be logged-in to download data

    Information about the sample:

    • Shape: Flat surface

    • Sample material: Tungsten Oxide

    • Elements: W/O

    • Sample composition: WO2/WO3

    Data acquisition parameters:

    • Photon source: Al Ka monochromatic

    Equipment and analysis software:

    • Software used: aanalyzer

    aanalyzer_727_image_14.jpg
  • Oxigeno para aluminio oxidado
    Read more

    Information about the sample:

    • Sample material: ?

    • Elements: ?

    • Sample composition: ?

    Data acquisition parameters:

    • Pass energy: ?

    • Take-off angle: ?

    Equipment and analysis software:

    • Brand: ?

    • Model: ?

    • Spectrometer mode: ?

    xpsoasis_228_image_100.jpg
  • Read more

    Files :

    • You must be logged-in to download data

    Information about the sample:

    • Sample material: Aluminum Oxide

    • Elements: Al. O

    • Sample composition: Al2O3, AlO

    Data acquisition parameters:

    • Photon source: Al Ka monochromatic

    • Pass energy: 10

    • Take-off angle: 85, 75, 65

    Equipment and analysis software:

    • Software used: aanalyzer

    aanalyzer_719_image_14.jpg
  • Read more

    Files :

    • You must be logged-in to download data

    Information about the sample:

    • Shape: Flat surface

    • Sample material: Tungsten

    • Elements: W/O

    • Sample composition: WO2/WO3

    Data acquisition parameters:

    • Photon source: Al Ka monochromatic

    • Pass energy: 15

    • Take-off angle: 85

    Equipment and analysis software:

    • Software used: aanalyzer

    aanalyzer_726_image_14.jpg
  • Read more

    Files :

    • You must be logged-in to download data

    Information about the sample:

    • Shape: Flat surface

    • Sample material: Tungsten

    • Elements: W/O

    • Sample composition: WO2/WO3

    Data acquisition parameters:

    • Photon source: Al Ka monochromatic

    • Pass energy: 15

    • Take-off angle: 85

    Equipment and analysis software:

    • Software used: aanalyzer

    aanalyzer_725_image_14.jpg
  • Read more

    Files :

    • You must be logged-in to download data

    Information about the sample:

    • Sample material: tungsten

    • Elements: W

    • Sample composition: W

    Equipment and analysis software:

    • Software used: aanalyzer

    aanalyzer_722_image_14.jpg
  • Read more

    Files :

    • You must be logged-in to download data

    Information about the sample:

    • Shape: Flat surface

    • Sample material: Tungsten

    • Elements: W

    • Sample composition: W/W-Ox

    Data acquisition parameters:

    • Photon source: Al Ka monochromatic

    • Pass energy: 15

    • Take-off angle: 85

    Equipment and analysis software:

    • Software used: aanalyzer

    aanalyzer_723_image_14.jpg
  • Read more

    Files :

    • You must be logged-in to download data

    Information about the sample:

    • Sample material: Tungten

    • Elements: W/O

    • Sample composition: WO3/WO2

    Data acquisition parameters:

    • Photon source: Al Ka monochromatic

    • Pass energy: 15

    • Take-off angle: 90

    Equipment and analysis software:

    • Software used: aanalyzer

    aanalyzer_724_image_14.jpg
  • XPS fitting of Cr2p. Sample were oxidized at atmospheric conditions for 15 min
    Read more

    Information about the sample:

    • Shape: Flat surface

    • Sample composition: Cr2O3,CrO3

    Data acquisition parameters:

    • Pass energy: 10

    Equipment and analysis software:

    • Brand: Thermoficher

    • Model: Alpha110

    • Spectrometer mode: MonoXPS

    xpsoasis_92_image_100.jpg
  • This is an alternative fit for the data of the paper 4. "Oxidation mechanism of metallic chromium at room temperature". https://doi.org/10.1016/j.apsusc.2020.148636 I use a doble lorentzina peak for the main peaks plus and a doblet of Voigt.
    Read more

    Files :

    • You must be logged-in to download data

    Information about the sample:

    • Sample material: Cr Metal

    • Elements: Cr

    Data acquisition parameters:

    • Photon source: Al Ka monochromatic

    • Pass energy: 15

    • Take-off angle: 85

    Equipment and analysis software:

    • Brand: Thermofisher

    • Model: Alpha 110

    • Software used: aanalyzer

    aanalyzer_699_image_14.jpg
  • Pure metalic chromium deposited by sublimation (99.999 purity, Sigma Aldrich). Data hace already published in Oxidation mechanism of metallic chromium at room temperature”, Applied Surface Science 542 (2021). https://doi.org/10.1016/j.apsusc.2020.148636
    Read more

    Files :

    • You must be logged-in to download data

    Information about the sample:

    • Shape: Flat surface

    • Sample material: Metallic Cr

    Data acquisition parameters:

    • Photon source: Al Ka monochromatic

    • Pass energy: 10

    • Take-off angle: 35-85

    Equipment and analysis software:

    • Brand: Thermofisher

    • Model: Alpha 110

    • Software used: AAnalyzer

    xpsoasis_397_image_100.jpg
  • Read more

    Equipment and analysis software:

    • Software used: AAnalyzer

    xpsoasis_456_image_100.jpg
  • Read more

    Files :

    • You must be logged-in to download data

    Equipment and analysis software:

    • Software used: AAnalyzer

    xpsoasis_448_image_100.jpg
  • Fitting of the S 2p photoemission spectrum for the element (research grade), data were obtained from the PHI Handbook
    Read more

    Files :

    • You must be logged-in to download data

    Information about the sample:

    • Sample material: Sulfur

    • Elements: S

    Data acquisition parameters:

    • Photon source: Al Ka

    Equipment and analysis software:

    • Software used: aanalyzer

    aanalyzer_734_image_14.jpg
  • Read more

    Files :

    • You must be logged-in to download data

    Information about the sample:

    • Sample material: Sulfur

    • Elements: S, Ta

    • Sample composition: TaS2

    Data acquisition parameters:

    • Photon source: Al Ka monochromatic

    Equipment and analysis software:

    • Software used: aanalyzer

    aanalyzer_751_image_14.jpg
  • Read more

    Files :

    • You must be logged-in to download data

    Data acquisition parameters:

    • Photon source: Al Ka monochromatic

    • Pass energy: 15

    • Take-off angle: 85

    Equipment and analysis software:

    • Software used: aanalyzer

    aanalyzer_924_image_14.jpg
  • Read more

    Files :

    • You must be logged-in to download data

    Data acquisition parameters:

    • Photon source: Al Ka monochromatic

    • Pass energy: 15

    • Take-off angle: 85

    Equipment and analysis software:

    • Software used: aanalyzer

    aanalyzer_923_image_14.jpg
  • Fluorine obtained during sublimation of metallic Yttrium (Sigma Aldrish 99.9%). The presence of fluorine could be because it is used during the yttrium purification. Data obtained at different currents used during sublimation. Flourine increases as current increase
    Read more

    Files :

    • You must be logged-in to download data

    Information about the sample:

    • Shape: Flat surface

    • Sample material: Flourine

    • Elements: F

    Data acquisition parameters:

    • Photon source: Al Ka monochromatic

    • Pass energy: 15

    • Take-off angle: 85

    Equipment and analysis software:

    • Brand: Thermofisher

    • Model: Alpha110

    • Spectrometer mode: MonoXPS

    • Software used: AAnalyzer

    xpsoasis_422_image_100.jpg
  • The use of the spectrum requires acknowledging https://xpslibrary.com/, the data is copyrighted.
    Read more

    Information about the sample:

    • Sample material: GaAs

    • Elements: Ga, As, O

    Data acquisition parameters:

    • Photon source: Al Ka monochromatic

    • Pass energy: 54.92

    • Take-off angle: 90

    Equipment and analysis software:

    • Software used: AAnalyzer

    xpsoasis_557_image_100.jpg
  • Read more

    Information about the sample:

    • Shape: Flat surface

    • Sample material: Vanadium Oxide

    • Elements: V, O

    • Sample composition: VxOy

    Data acquisition parameters:

    • Photon source: Al Ka monochromatic

    • Pass energy: 15

    • Take-off angle: 90

    Equipment and analysis software:

    • Brand: Thermofisher

    • Model: Alpha110

    • Software used: AAnalyzer

    xpsoasis_616_image_100.jpg
  • Muestras en polvo de PdCo propiedad del Centro de Investigación y Desarrollo Tecnológico en Electroquímica, S. C.
    Read more

    Information about the sample:

    • Sample material: PdCo

    • Elements: Co

    Data acquisition parameters:

    • Photon source: Al Ka

    Equipment and analysis software:

    • Software used: aanalyzer

    aanalyzer_697_image_14.jpg
  • Muestras en polvo de PdCo propiedad del Centro de Investigación y Desarrollo Tecnológico en Electroquímica, S. C.
    Read more

    Information about the sample:

    • Sample material: PdCo

    • Elements: Pd

    Data acquisition parameters:

    • Photon source: Al Ka

    Equipment and analysis software:

    • Software used: aanalyzer

    aanalyzer_698_image_14.jpg

Full name:

Orlando Cortazar-Martínez

Title:

Doctor

organization:

Cinvestav, Queretaro

Country:

Mexico

This user is:

Moderator in elements:

Moderator in forum:

Number of post in database:

0

Number of post:

Total: 12

(8 posts ) (5 posts ) (4 posts ) (3 posts ) (2 posts ) (2 posts ) (2 posts ) (1 posts ) (1 posts ) (1 posts ) (1 posts ) (1 posts )